Immuniteit:
• Enclosure port
o RF-field, AM modulated EN55024/61000-4-3 Radiated 80 .. 1000 MHz Perf. A Antenne, shielded room, 10/3 Vrms/m
o ESD EN55024/61000-4-2 Perf. B 8kV air, 6kV contact
• Signal / telecom ports
o RF com mode, AM mod. EN55024/61000-4-6 Conducted 0.15 .. 80 MHz Perf. A Cables > 3m, CDN or clamp
o Fast transients EN55024/61000-4-4 Conducted Perf. B Cables > 3m, Capacitive coupling clamp
• Input DC port
o RF com mode, AM mod. EN55024/61000-4-6 Conducted 0.15 .. 80 MHz Perf. A Cables > 3m, CDN or clamp
o Fast transients EN55024/61000-4-4 Conducted Perf. B Cables > 3m, Capacitive coupling clamp
• AC input / output ports
o RF com mode, AM mod. EN55024/61000-4-6 Conducted 0.15 .. 80 MHz Perf. A CDN
o Fast transients EN55024/61000-4-4 Conducted Perf. B Capacitive coupling clamp
o Surges EN55024/61000-4-5 Conducted Perf. B CDN
o Voltage dips and int. EN55024/61000-4-11 Perf. B/C
RED:
• EN 300 330
o Transmitter
▪ Permitted range of operating frequencies
▪ Limits for transmitters
▪ Limits range of modulation bandwidth
▪ Transmitter spurious radiated
o Receiver
▪ Rx adjacent channel selectivity
▪ Rx blocking
▪ Rx spurious emission
Rapportage
Wij kunnen uiteraard ook de rapportage voor u verzorgen eventueel in de vorm van een Technisch Constructie Dossier (TCD).